Motor terminology
Time:2013-07-29 16:43:30Source:View Count:1515
Rating
A rating specific operating limit of a motor. For example, there are rating for the output,voltage,current,frequency,torque,speed etc.Of a motor. For the control of temperature, there are continuous rating and short-time rating.
Continuous Rating & Short-time Rating
Continuous rating means motor can run at a rated output continuously,and short-time rating means motor can run a rated output only within the time specified.
Output
Output is the power can generate within a given time and is determined by the speed and torque of the motor. It can be calculated by the following formula:
Output(Kw)=(T×N)/97400
T:Torque(Kgcm )
N:Speed(rpm)
1HP:0.746Kw
Starting torque